Treffer: A statistical approach to automated analysis of the low‐contrast object detectability test for the large ACR MRI phantom.
Weitere Informationen
Background: Regular quality control checks are essential to ensure the quality of MRI systems. The American College of Radiology (ACR) has developed a standardized large phantom test protocol for this purpose. However, the ACR protocol recommends manual measurements, which are time‐consuming, labor‐intensive, and prone to variability, impacting accuracy and reproducibility. Although some aspects of the ACR evaluation have been automated or semi‐automated, tests like low‐contrast object detectability (LCOD), remain challenging to automate. LCOD involves assessing the visibility of objects at various contrast levels. Purpose: The purpose of this research is to propose and evaluate an automated approach for LCOD testing in MRI. Methods: The automated Python code generates a one‐dimensional profile of image intensities along radial paths from the center of the contrast disk. These profiles are compared to templates created from the disc's geometric information using general linear model statistical tests. A total of 80 image volumes (40 T1‐ and 40 T2‐weighted) were assessed twice by two human evaluators and the proposed Python code. Results: Human raters showed intra‐rater variability (Cohen's Kappa 0.941, 0.962), while the Python code exhibited perfect intra‐rater agreement. Inter‐rater agreement between the code and humans was comparable to human‐to‐human agreement (Cohen's Kappa 0.878 between the two human raters vs. 0.945, and 0.783 between the code and human raters). A stress test revealed both human raters and the code assigned higher scores to lower bandwidth images and lower scores to higher bandwidth images. Conclusion: The proposed automated method eliminates intra‐rater variability and achieves strong inter‐rater agreement with human raters. These findings suggest the method is reliable and suitable for clinical settings, showing high concordance with human assessments. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Applied Clinical Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)