Sauf mention contraire ci-dessus, le contenu de cette notice bibliographique peut être utilisé dans le cadre d’une licence CC BY 4.0 Inist-CNRS / Unless otherwise stated above, the content of this bibliographic record may be used under a CC BY 4.0 licence by Inist-CNRS / A menos que se haya señalado antes, el contenido de este registro bibliográfico puede ser utilizado al amparo de una licencia CC BY 4.0 Inist-CNRS
Metrology
Weitere Informationen
Automatic processing of IR sequences is a desirable target in Thermal Non-Destructive Evaluation (TNDE) of materials. Unfortunately, this task is made difficult by the presence of many undesired signals that corrupt the useful information detected by the IR camera. In this paper the Principal Component Analysis (PCA) is used to process IR image sequences to extract features and reduce redundancy by projecting the original data onto a system of orthogonal components. As a thermographic sequence contains information both in space and time, the way of applying the PCA to these data cannot be straightforwardly borrowed from typical applications of the PCA where the information is mainly spatial (e.g. remote sensing, face recognition). This peculiarity has been analysed and the results are reported. Finally, in addition to the use of the PCA as an unsupervised method, its use in a learning and measuring configuration is considered.