Sauf mention contraire ci-dessus, le contenu de cette notice bibliographique peut être utilisé dans le cadre d’une licence CC BY 4.0 Inist-CNRS / Unless otherwise stated above, the content of this bibliographic record may be used under a CC BY 4.0 licence by Inist-CNRS / A menos que se haya señalado antes, el contenido de este registro bibliográfico puede ser utilizado al amparo de una licencia CC BY 4.0 Inist-CNRS
Physics: fluid mechanics
Weitere Informationen
In this paper an approach to the validation of transient numerical simulations of turbulent flows through the use of time resolved PIV data is presented and applied to the case of turbulent flow within a simplified model of printed circuit board (PCB) enclosure. The comparison between numerical and experimental data is not limited here to the time averaged fields, but transient flow structures are also addressed. With this purpose a set of conditionally sampled averages, or cluster averages, are obtained through a Fuzzy Clustering technique. Further, the time history of the flow is analyzed on the base of this set of cluster averages, yielding time sequence relations among them that simplify their interpretation in terms of flow dynamics. In this way, events of alternate vortex shedding have been identified in a selected portion of the flow, and showed to exist in both numerical and experimental sets of data.